FLUKE – Bộ KIT HVAC Fluke 116/323 (Bao gồm bộ đo vạn năng & ampe kìm)
Model: Fluke 116/323
Hãng sản xuất: FLUKE – MỸ
Tính năng bộ KIT HVAC Fluke 116/323:
Fluke116 Digital Multimeter:
- Fluke 116 HVAC Multimeter with Temperature and Microamps.
- TL175 Hard Point Test Lead Set.
- TPak ToolPak Magnetic Meter Hanging Strap.
- Flexible Cuff Pipe Clamp Thermocouple.
- 80BK Integrated Temperature Probe.
- 80AK-A Thermocouple Adapter.
- C115 Deluxe Soft Carrying Case with Shoulder Strap.
Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.
- 400 A ac current measurement.
- 600 V ac and dc voltage measurement.
- True-rms ac voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety rating.
Thông số kỹ thuật bộ KIT HVAC Fluke 116/323:
Maximum voltage between any terminal and earth ground
|
600 V
|
Surge protection
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
|
Display
|
6,000 counts, updates 4 per second
|
Bar graph
|
33 segments, updates 32 per second
|
Operating Temperature
|
-10 °C to + 50 °C
|
Storage Temperature
|
-40 °C to + 60 °C
|
Battery type
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
|
Battery Life
|
400 hours typical, without backlight
|
Accuracy Specifications
| ||
DC millivolts
|
Range
|
600.0 mV
|
Resolution
|
0.1 mV
| |
Accuracy
|
± ([% of reading] + [counts]): 0.5% + 2
| |
DC volts
|
Range/Resolution
|
6.000 V / 0.001 V
|
Range/Resolution
|
60.00 V / 0.01 V
| |
Range/Resolution
|
600.00 V / 0.1 V
| |
Accuracy
|
± ([% of reading] + [counts]): 0.5% + 2
| |
Auto volts
|
Range
|
600.0 V
|
Resolution
|
0.1 V
| |
Accuracy
|
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) | |
AC millivolts1 true-rms
|
Range
|
600.0 mV
|
Resolution
|
0.1 mV
| |
Accuracy
|
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) | |
AC volts1 true-rms
|
Range/Resolution
|
6.000 V / 0.001 V
|
Range/Resolution
|
60.00 V / 0.01 V
| |
Range/Resolution
|
600.0 V / 0.1 V
| |
Accuracy
|
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) | |
Continuity
|
Range
|
600 Ω
|
Resolution
|
1 Ω
| |
Accuracy
|
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
| |
Ohms
|
Range/Resolution
|
600.0 Ω / 0.1 Ω
|
Range/Resolution
|
6.000 kΩ / 0.001 kΩ
| |
Range/Resolution
|
60.00 kΩ / 0.01 kΩ
| |
Range/Resolution
|
600.0 kΩ / 0.1 kΩ
| |
Range/Resolution
|
6.000 MΩ / 0.001 MΩ
| |
Accuracy
|
0.9 % + 1
| |
Range/Resolution
|
40.00 MΩ / 0.01 MΩ
| |
Accuracy
|
1.5 % + 2
| |
Diode Test
|
Range/Resolution
|
2.000 V / 0.001 V
|
Accuracy
|
0.9% + 2
| |
Capacitance
|
Range/Resolution
|
1000 nF / 1 nF
|
Range/Resolution
|
10.00 μF / 0.01 μF
| |
Range/Resolution
|
100.0 μF / 0.1 μF
| |
Range/Resolution
|
9999 μF / 1 μF
| |
Range/Resolution
|
100 μF to 1000 μF
| |
Accuracy
|
1.9% + 2
| |
Range/Resolution
|
> 1000 μF
| |
Accuracy
|
5% + 20%
| |
LoZ capacitance
|
Range
|
1 nF to 500 μF
|
Accuracy
|
10% + 2 typical
| |
Temperature2 (Type-K thermocouple)
|
Range/Resolution
|
-40 °C to 400 °C / 0.1 °C
|
Accuracy
|
1% + 102
| |
Range/Resolution
|
-40 °F to 752 °F / 0.2 °F
| |
Accuracy
|
1% + 182
| |
AC μamps true-rms (45 Hz to 500 Hz)
|
Range/Resolution
|
600.0 μA / 0.1 μA
|
Accuracy
|
1.0% + 2
| |
DC μamps
|
Range/Resolution
|
600.0 μA / 0.1 μA
|
Accuracy
|
1.0% + 2
| |
Hz (V or A input)2
|
Range/Resolution
|
99.99 Hz / 0.01 Hz
|
Range/Resolution
|
999.99 Hz / 0.1 Hz
| |
Range/Resolution
|
9.999 Hz / 0.001 Hz
| |
Range/Resolution
|
50.00 Hz / 0.01 Hz
| |
Accuracy
|
0.1% + 2
| |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications
| |
Size
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
|
Weight
|
550 g
|
Warranty
|
3 years
|
Fluke 323 True-rms Clamp Meter:
Specifications
| ||
AC current
|
Range 400.0 A
| |
Accuracy
|
2 % ± 5 digits
(45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz) | |
AC voltage
|
Range
|
600.0 V
|
Accuracy
|
1.5 % ± 5 digits
| |
DC voltage
|
Range
|
600.0 V
|
Accuracy
|
1.0 % ± 5 digits
| |
Resistance
|
Range
|
400.0 Ω/ 4000 Ω
|
Accuracy
|
1.0 % ± 5 digits
| |
Continuity
|
≤ 70 Ω
| |
AC response
|
True-rms
| |
Data hold
|
Yes
| |
Size
|
H x W x D (mm)
|
207 x 75 x 34
|
Max wire diameter
|
30 mm (600 MCM)
| |
Weight
|
265 g
| |
Category rating
|
CAT III 600 V
CAT IV 300 V | |
Warranty
|
Two-year
| |