FLUKE – Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +
Model: Fluke 414D/62 MAX +
Hãng sản xuất: FLUKE – MỸ
Tham khảo: http://www.fluke.com/fluke/vnen/laser-distance-meters/fluke-414d-62-max-plus-kit.htm?PID=75996
Tính năng Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +:
The 414D reduces errors, saves time and money.
- The most advanced laser technology for distance measurement.
- Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).
- Quick calculation of area (square feet/meters) and volume.
- Pythagoras function indirectly measures height via two other measurements.
- Stores up to five measurement results.
- Battery life of 3000 measurements with automatic shut-off feature.
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
Thông số kỹ thuật Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +:
Distance Measurement
| ||
Typical Measuring Tolerance[1]
|
± 2.0 mm [3]
| |
Maximum Measuring Tolerance[2]
|
± 3.0 mm [3]
| |
Range at Leica target plate GZM26
|
50 m / 165 ft
| |
Typical Range[1]
|
40 m / 130 ft
| |
Range at unfavorable condition[4]
|
35 m / 115 ft
| |
Smallest unit displayed
|
1 mm / 1/16 in
| |
∅ laser point at distances
|
6 /30 / 60 mm
(10 / 50 / 100 m) | |
Tilt measurement
| ||
Measuring tolerance to laser beam[5]
|
No
| |
Measuring tolerance to housing[5]
|
No
| |
Range
|
No
| |
General
| ||
Laser class
|
2
| |
Laser type
|
635 nm, <1 mW
| |
Protection class
|
IP40
| |
Automatic laser off
|
After 90 seconds
| |
Automatic power off
|
after 180 seconds
| |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
|
Up to 3,000
measurements | |
Size (H X W X L)
|
116mm Length
53mm Width 33mm Depth | |
Weight (with batteries)
|
113 g
| |
Temperature range: Storage Operation
|
-25 °C to +70°C
(-13 °F to +158 °F) 0 °C to +40 °C (32 °F to +104 °F) | |
Calibration cycle
|
Not applicable
| |
Maximum altitude
|
3000 m
| |
Maximum relative humidity
|
85% at 20 °F to 120°F
(-7 °C to 50 °C) | |
Safety
|
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II) | |
EMC
|
EN 55022:2010
EN 61000-4-3:2010 EN 61000-4-8:2010 | |
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C. [3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. [4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux. [5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. | ||
Fluke 62 MAX+ Infrared Thermometer
Specifications
| ||
Temperature Range
|
-30 °C to 650 °C (-22 °F to 1202 °F)
| |
Accuracy
|
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 | |
Response Time (95%)
|
Fluke 62 MAX+
|
<300 ms (95% of reading)
|
Spectral Response
|
8 to 14 microns
| |
Emissivity
|
0.10 to 1.00
| |
Optical Resolution
|
12:1 (calculated at 90% energy)
| |
Display Resolution
|
0.1 °C (0.2 °F)
| |
Repeatability of Readings
|
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
| |
Power
|
AA battery
| |
Battery Life
|
8 hours with laser and backlight on
| |
Physical Specifications
|
Weight
|
255 g (8.99 oz)
|
Size
|
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
| |
Operating Temperature
|
0 °C to 50 °C (32 °F to 122 °F)
| |
Storage Temperature
|
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
| |
Operating Humidity
|
10 % to 90 % RH non-condensing at 30 °C (86 °F)
| |
Operating Altitude
|
2000 meters above mean sea level
| |
Storage Altitude
|
12,000 meters above mean sea level
| |
IP Rating
|
IP 54 per IEC 60529
| |
Drop Test
|
3 meters
| |
Vibration and Shock
|
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
| |
EMC
|
EN 61326-1:2006 EN 61326-2:2006
| |
Standards and Agency Approval
|
Compliance
|
EN/IEC 61010-1: 2001
|
Laser Safety
|
FDA and EN 60825-1 Class II
|
Không có nhận xét nào: