FLUKE – Đồng hồ điện vạn năng kỹ thuật số dòng cơ bản Fluke 101
Model: Fluke 101
Hãng sản xuất: FLUKE – MỸ
Tính năng Đồng hồ điện vạn năng kỹ thuật số dòng cơ bản Fluke 101:
- Basic dc accuracy 0.5%
- CAT III 600 V safety rated
- Diode and continuity test with buzzer
- Small lightweight design for one-handed use
- Rugged, durable design
- Automatic shutdown
- Battery is easy to replace
Thông số kỹ thuật Đồng hồ điện vạn năng kỹ thuật số dòng cơ bản Fluke 101:
Electrical Specifications
|
V AC (40-500Hz)
|
Range
|
600.0 mV 6.000 V 60.00 V 600.0 V
|
Resolution
|
0.1 mV 0.001 V 0.01 V 0.1 V
|
Accuracy
|
3.0%±3 digit 1.0%±3 digit
|
V DC
|
Range
|
6.000 V 60.00 V 600.0 V
|
Resolution
|
0.001 V 0.01 V 0.1 V
|
Accuracy
|
0.5%±3 digit
|
Resistance Ohms
|
Range
|
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ
|
Resolution
|
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ
|
Accuracy
|
0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit
|
Capacitance
|
Range
|
50.00 nF 500.0 nF 5.000 μF 50.00 μF 100.0 μF
|
Resolution
|
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF
|
Frequency (10 Hz – 100 kHz)
|
Range
|
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz
|
Resolution
|
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz
|
Duty Cycle
|
Range
|
0.1 % to 99.9 %
|
Resolution
|
0.1 %
|
General Specifications
|
CAT Rating
|
CAT III 600 V
|
V AC Range
|
600.0 V
|
V DC Range
|
600.0 V
|
Ohms Range
|
40.00 MΩ
|
Auto Shutoff
|
Y
|
Continuity
|
Y
|
Capacitor
|
100.0 μF
|
Frequency
|
100.0 kHz
|
Hold
|
No
|
Duty Cycle
|
Yes
|
Size
|
130 mm x 65 mm x 27mm
|
Weight
|
160 g
|
Battery
|
Two AAA
|
Warranty
|
1 year
|
Environmental Specifications
|
Operating Temperature
|
0 °C to +40 °C
|
Storage Temperature
|
-30 °C to +60 °C
|
Operating Humidity
|
Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without Condensation)
|
Operating Humidity, 40 MΩ
|
80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
|
Operating Altitude
|
2,000 meters
|
Storage Altitude
|
12,000 meters
|
IP Rating
|
IP 40 per IEC 60529
|
Vibration Requirements
|
MIL-PRF-28800F, Class 2
|
Drop Test Requirements
|
-10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39.
|
EMI, RFI, EMC
|
Must meet all applicable requirements in IEC/EN 61326-1
|
Absorption/Corrosion
|
Per Fluke SOP 39.1
|
Temperature Coefficients
|
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC
|
|
|
| |